A side channel blower (also known as a regenerative or ring blower) is a tough, oil-free air pump. It moves a large volume of air at a steady pressure or suction, runs relatively quietly, and has just one moving part, so it needs very little maintenance and tends to last for years.
A powerful 3.3 kW motor makes this a large, high-output machine, moving up to 87 cubic metres of air per hour. It can blow air at up to 750 mbar of pressure or pull a vacuum of up to 500 mbar. As a rule of thumb, the bigger these numbers, the more push or pull the blower can deliver. It requires a three-phase industrial electrical supply.
Being a two-stage (double) blower, it develops noticeably more pressure and suction than a single-stage unit of a similar size. That makes it a good choice when the job needs stronger push or pull rather than sheer volume of air.
Typically used for: aerating fish farms, ponds and wastewater treatment tanks; pneumatic conveying of powders and granules along pipework; supplying air to packaging and blown-film lines.
Specifications
| Frequency |
50 Hz |
60 Hz |
| Motor power (kW) |
3.3 |
3.8 |
| Voltage (V) |
200-240△345-415Y |
220-275△380-480Y |
| Rated current (A) |
13.0△/7.5Y |
13.8△/8.0Y |
| Max airflow (m³/h) |
87 |
105 |
| Max vacuum (mbar) |
-500 |
-510 |
| Max pressure (mbar) |
750 |
850 |
| Sound level dB(A) |
61 |
66 |
Northey part number: NSG42-T3.3-1.25 (50Hz) / NSG42-T3.8-1.25 (60Hz)
Weight: 39 kg